16MM 1/2GPH 16MM 1GPH 16MM 2GPH 20MM 1/2 GPH 20MM 1GPH 20MM 2GPH

Pressure Compensation Flow Curve- 20 MM 1/2 GPH

Friction Loss Curve- 20 MM 1/2 GPH

Application Rate (Per Square foot)- 16 MM 1/2 GPH

 1/2 GAL 20 MM Application Rates
Pressure (psi) Flow (GPH) Lateral Spacing  Max-Emitter Spacing (Inches) GPM/SQ FOOT
14 16 18 20 22 24
10 0.39 14 0.0053 0.0046 0.0041 0.0037 0.0034 0.0031
16 0.0046 0.0040 0.0036 0.0032 0.0029 0.0027
18 0.0041 0.0036 0.0032 0.0029 0.0026 0.0024
20 0.0037 0.0032 0.0029 0.0026 0.0023 0.0022
22 0.0034 0.0029 0.0026 0.0023 0.0021 0.0020
24 0.0031 0.0027 0.0024 0.0022 0.0020 0.0018
15 0.53 14 0.0065 0.0057 0.0050 0.0045 0.0041 0.0038
16 0.0057 0.0050 0.0044 0.0040 0.0036 0.0033
18 0.0050 0.0044 0.0039 0.0035 0.0032 0.0029
20 0.0045 0.0040 0.0035 0.0032 0.0029 0.0027
22 0.0041 0.0036 0.0032 0.0029 0.0026 0.0024
24 0.0038 0.0033 0.0029 0.0027 0.0024 0.0022
20 0.65 14 0.0077 0.0068 0.0060 0.0054 0.0049 0.0045
16 0.0068 0.0059 0.0053 0.0047 0.0043 0.0039
18 0.0060 0.0053 0.0047 0.0042 0.0038 0.0035
20 0.0054 0.0047 0.0042 0.0038 0.0034 0.0032
22 0.0039 0.0034 0.0030 0.0027 0.0025 0.0023
24 0.0045 0.0039 0.0035 0.0032 0.0029 0.0026
 